4-2.5
Receiver Sensitivity Testing
(20 dB Quieting)
1. With the cursor located within the RF
Control zone, press the
MON
softkey to
remove input signal from the radio.
MON
GEN
DUPLEX
Monitor Mode
2. With the cursor located within the Display
Control zone, press the
AC VOLTS
softkey
to display the ac voltmeter:
DC
VOLTS
RF
DISPLAY
AC Meter
RF
SCAN
AC
VOLTS
3. Turn on the receiver (unsquelched). In-
crease the receiver volume control to feed
audio noise to the analyzer (at least 1/4 the
rated audio power). Record the noise
reading in dBm.
Meter: AC VOLTMETER
Range: AUTO
0.050 VAC
0
1
+10.0 dBm
4. With the cursor within the RF Control zone,
press the
GEN
softkey.
MON
GEN
DUPLEX
Generator Mode
Softkey
5. Within the Audio Control zone, set the
modulation off.
Mod Sum:
0.00 kHz
Fixed 1kHz:
Synth:
3.00 kHz
7 kHz
Format Sel:
DPL
Code
021
DTMF:
0.00 kHz
Code: 1234567890#ABCD
External:
0.00 kHz
x
x
x
x
6. Within the RF Control zone, adjust the RF
output level until the noise reading is less
than 20 dB from the value recorded in
step 3. Refer to your radio's service manual
to determine if any adjustments are
required.
RF Control:
Preset: - -
B/W: NB
GENERATE
Freq:
Output Level:
-112 dB
816.5000 MHz
Mon RF In:
RF I/O
Modulation Type:
FM
Adjust as
Required
NOTE
To convert the RF output level to uV or dBV,
locate the cursor within the Display Control
zone and press the
RF DISPLAY
softkey.
Locate the cursor to units used for Lvl: and
select the required unit using the softkeys.
73
Summary of Contents for R2600 Series
Page 8: ...3 7 1 3 AC DC Voltmeter 41 3 7 1 4 INT DIST EXT DIST Meter 43 v...
Page 46: ...This Page Intentionally Left Blank xxxvi...
Page 66: ...DISPLAY ZONE RF ZONE AUDIO ZONE Figure 3 1 Screen Zone Arrangement 20...
Page 68: ...Figure 3 2 System Help 22...
Page 83: ...Figure 3 11 General Sequence Mode Select 37...
Page 85: ...39 Figure 3 12 RF Display Zone...
Page 88: ...Figure 3 14 Digital Voltmeter Screens 42...
Page 102: ...Figure 3 22 Bar Graphs 56...
Page 107: ...Figure 3 24 Memory Screens 61...
Page 128: ...This Page Intentionally Left Blank 82...
Page 202: ...This Page Intentionally Left Blank 156...
Page 205: ...Figure 11 1 R 2670 with SECURENET Option Housing 159...
Page 206: ...This Page Intentionally Left Blank 160...
Page 218: ...Figure 13 8 Test Key Programming Display Figure 13 9 External Key Programming Display 172...
Page 225: ...Figure 13 12 Duplex Mode Display Zone 179...
Page 234: ...VOICE Figure 13 17 CLEAR SCOPE Markers 188...
Page 236: ...This Page Intentionally Left Blank 190...
Page 249: ...Figure 14 8 SECURENET CLEAR SCOPE Display of Output Modulation 203...
Page 252: ...This Page Intentionally Left Blank 206...
Page 256: ...210 This Page Intentionally Left Blank...
Page 267: ...Figure 17 7 Encryption Select Display Figure 17 7 Encryption Select Display 221 221...
Page 286: ...This Page Intentionally Left Blank 240...
Page 291: ...Figure 18 1 Radio BER Test Mode Audio Zone Figure 18 2 Radio BER Test Mode BER Meter 245...
Page 293: ...Figure 18 4 Receive BER 247...
Page 298: ...Figure 18 6 ASTRO CLEAR SCOPE Display of Output Modulation 252...
Page 304: ...Figure 21 1 PROJ 25 Version Screen Figure 21 2 PROJ 25 Options Screen 258...
Page 309: ...Figure 21 6 SET UP Display Screen Figure 21 7 Encryption Select Display 263...
Page 335: ...Figure 22 4 PROJ 25 CONV CLEAR SCOPE Display of Output Modulation 289...
Page 339: ...Figure 24 1 PROJ 25 Version Screen Figure 24 2 PROJ 25 Options Screen 293...
Page 354: ...Figure 25 3 Encryption Select Display Figure 25 4 Algorithm Select Display 308...
Page 369: ...B 6 This Page Intentionally Left Blank...
Page 379: ...This Page Intentionally Left Blank F 4...
Page 383: ...This Page Intentionally Left Blank H 2...
Page 389: ...J 4 This Page Intentionally Left Blank...
Page 393: ...This Page Intentionally Left Blank K 4...