C.7 LOGICAL NODES
APPENDIX C
C
ITPC: Teleprotection communication interfaces
---
K: LOGICAL NODES FOR MECHANICAL AND NON-ELECTRIC PRIMARY EQUIPMENT
KFAN: Fan
---
KFIL: Filter
---
KPMP: Pump
---
KTNK: Tank
---
KVLV: Valve control
---
M: LOGICAL NODES FOR METERING AND MEASUREMENT
MENV: Environmental information
---
MFLK: Flicker measurement name
---
MHAI: Harmonics or interharmonics
---
MHAN: Non phase related harmonics or interharmonics
---
MHYD: Hydrological information
---
MMDC: DC measurement
---
MMET: Meteorological information
---
MMTN: Metering
---
MMTR: Metering
---
MMXN: Non-phase-related measurement
Yes
MMXU: Measurement
Yes
MSQI: Sequence and imbalance
Yes
MSTA: Metering statistics
---
P: LOGICAL NODES FOR PROTECTION FUNCTIONS
PDIF: Differential
Yes
PDIR: Direction comparison
---
PDIS: Distance
Yes
PDOP: Directional overpower
---
PDUP: Directional underpower
---
PFRC: Rate of change of frequency
---
PHAR: Harmonic restraint
---
PHIZ: Ground detector
---
PIOC: Instantaneous overcurrent
Yes
PMRI Motor restart inhibition
---
PMSS: Motor starting time supervision
---
POPF: Over power factor
---
PPAM: Phase angle measuring
---
PRTR: Rotor protection
---
PSCH: Protection scheme
---
PSDE: Sensitive directional earth fault
---
PTEF: Transient earth fault
---
PTOC: Time overcurrent
Yes
PTOF: Overfrequency
---
PTOV: Overvoltage
Yes
PTRC: Protection trip conditioning
Yes
PTTR: Thermal overload
---
PTUC: Undercurrent
---
PTUF: Underfrequency
---
PTUV: Undervoltage
Yes
Table C–1: IEC 61850 LOGICAL NODES (Sheet 2 of 4)
NODES
UR-FAMILY
Summary of Contents for C60
Page 10: ...x C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 420: ...5 284 C60 Breaker Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 466: ...8 4 C60 Breaker Protection System GE Multilin 8 1 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 478: ...9 12 C60 Breaker Protection System GE Multilin 9 6 DISPOSAL 9 MAINTENANCE 9 ...
Page 492: ...A 14 C60 Breaker Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 648: ...E 10 C60 Breaker Protection System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Page 660: ...F 12 C60 Breaker Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 670: ...H 8 C60 Breaker Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 672: ...H 10 C60 Breaker Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 682: ...x C60 Breaker Protection System GE Multilin INDEX ...