GE Multilin
C60 Breaker Protection System
B-27
APPENDIX B
B.4 MEMORY MAPPING
B
3958
...Repeated for Field Contact Input9
3963
...Repeated for Field Contact Input 10
396E
...Repeated for Field Contact Input 11
3979
...Repeated for Field Contact Input 12
3984
...Repeated for Field Contact Input 13
398F
...Repeated for Field Contact Input 14
399A
...Repeated for Field Contact Input 15
39A5
...Repeated for Field Contact Input 16
39B0
...Repeated for Field Contact Input 17
39BB
...Repeated for Field Contact Input 18
39C6
...Repeated for Field Contact Input 19
39D1
...Repeated for Field Contact Input 20
39DC
...Repeated for Field Contact Input 21
39E7
...Repeated for Field Contact Input 22
39F2
...Repeated for Field Contact Input 23
39FD
...Repeated for Field Contact Input 24
3A08
...Repeated for Field Contact Input 25
3A13
...Repeated for Field Contact Input 26
3A1E
...Repeated for Field Contact Input 27
3A29
...Repeated for Field Contact Input 28
3A34
...Repeated for Field Contact Input 29
3A3F
...Repeated for Field Contact Input 30
3A4A
...Repeated for Field Contact Input 31
3A55
...Repeated for Field Contact Input 32
3A60
...Repeated for Field Contact Input 33
3A6B
...Repeated for Field Contact Input 34
3A76
...Repeated for Field Contact Input 35
3A81
...Repeated for Field Contact Input 36
3A8C
...Repeated for Field Contact Input 37
3A97
...Repeated for Field Contact Input 38
3AA2
...Repeated for Field Contact Input 39
3AAD
...Repeated for Field Contact Input 40
Field Unit Shared Inputs (Read/Write Setting) (16 modules)
3B00
Field Shared Input 1 ID
0 to 65535
---
1
F205
"SI 1"
3B06
Field Shared Input 1 Unit Origin 1
0 to 8
---
1
F256
0 (None)
3B07
Field Shared Input 1 Channel Origin 1
1 to 15
---
1
F001
1
3B08
Field Shared Input 1 Events
0 to 1
---
1
F102
1 (Enabled)
3B09
...Repeated for Field Shared Input 2
3B12
...Repeated for Field Shared Input 3
3B1B
...Repeated for Field Shared Input 4
3B24
...Repeated for Field Shared Input 5
3B2D
...Repeated for Field Shared Input 6
3B36
...Repeated for Field Shared Input 7
3B3F
...Repeated for Field Shared Input 8
3B48
...Repeated for Field Shared Input 9
3B51
...Repeated for Field Shared Input 10
3B5A
...Repeated for Field Shared Input 11
3B63
...Repeated for Field Shared Input 12
3B6C
...Repeated for Field Shared Input 13
3B75
...Repeated for Field Shared Input 14
3B7E
...Repeated for Field Shared Input 15
3B87
...Repeated for Field Shared Input 16
Field Unit Contact Outputs (Read/Write Setting) (8 modules)
3B90
Field Contact Output 1 ID (6 items)
---
---
---
F205
"FCO U /OUT"
Table B–10: MODBUS MEMORY MAP (Sheet 19 of 66)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for C60
Page 10: ...x C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 420: ...5 284 C60 Breaker Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 466: ...8 4 C60 Breaker Protection System GE Multilin 8 1 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 478: ...9 12 C60 Breaker Protection System GE Multilin 9 6 DISPOSAL 9 MAINTENANCE 9 ...
Page 492: ...A 14 C60 Breaker Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 648: ...E 10 C60 Breaker Protection System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Page 660: ...F 12 C60 Breaker Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 670: ...H 8 C60 Breaker Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 672: ...H 10 C60 Breaker Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 682: ...x C60 Breaker Protection System GE Multilin INDEX ...