GE Multilin
C60 Breaker Protection System
B-25
APPENDIX B
B.4 MEMORY MAPPING
B
3515
RTD Input 38 Value
-32768 to 32767
°C
1
F002
0
3516
RTD Input 39 Value
-32768 to 32767
°C
1
F002
0
3517
RTD Input 40 Value
-32768 to 32767
°C
1
F002
0
3518
RTD Input 41 Value
-32768 to 32767
°C
1
F002
0
3519
RTD Input 42 Value
-32768 to 32767
°C
1
F002
0
351A
RTD Input 43 Value
-32768 to 32767
°C
1
F002
0
351B
RTD Input 44 Value
-32768 to 32767
°C
1
F002
0
351C
RTD Input 45 Value
-32768 to 32767
°C
1
F002
0
351D
RTD Input 46 Value
-32768 to 32767
°C
1
F002
0
351E
RTD Input 47 Value
-32768 to 32767
°C
1
F002
0
351F
RTD Input 48 Value
-32768 to 32767
°C
1
F002
0
Ohm Input Values (Read Only) (2 modules)
3520
Ohm Inputs 1 Value
0 to 65535
Ohm
1
F001
0
3521
Ohm Inputs 2 Value
0 to 65535
Ohm
1
F001
0
Expanded Direct Input/Output Status (Read Only)
3560
Direct Device States, one per register (16 items)
0 to 1
---
1
F155
0 (Offline)
3570
Direct Input States, one per register (96 items)
0 to 1
---
1
F108
0 (Off)
RADIUS Configuration (Read/Write Setting)
3735
Primary RADIUS IP Address
0 to 4294967295
---
1
F003
0
3737
Primary Authentication Port
1 to 65535
---
1
F001
1812
3738
Primary Accounting Port
1 to 65535
---
1
F001
1813
3739
Secondary RADIUS IP Address
0 to 4294967295
---
1
F003
0
373B
Secondary Authentication Port
0 to 65535
---
1
F001
1812
373D
Secondary Accounting Port
0 to 65535
---
1
F001
1813
373F
RADIUS Authentication Method
---
---
1
F619
0 (EAP-TTLS)
3740
RADIUS Vendor ID
1 to 65535
---
1
F001
2910
3741
Authentication Timeout
0 to 9999
sec
1
F001
10
3742
Authentication Retries
0 to 9999
---
1
F001
3
3743
RADIUS Authentication Shared Secret
---
---
---
F202
(none)
PTP Basic Configuration (Read/Write Setting)
3750
PTP Strict Power Profile
0 to 1
---
1
F102
0 (Disabled)
3751
PTP Domain Number
0 to 255
---
1
F001
0
3752
PTP VLAN Priority
0 to 7
---
1
F001
4
3753
PTP VLAN ID
0 to 4095
---
1
F001
0
3754
Undefined (2 items)
0 to 1
---
1
F001
0
PTP Port Configuration (Read/Write Setting) (3 modules)
3756
PTP Port 1 Function
0 to 1
---
1
F102
0 (Disabled)
3757
PTP Port 1 Path Delay Adder
0 to 60000
ns
1
F001
0
3758
PTP Port 1 Path Delay Asymmetry
-1000 to 1000
ns
1
F002
0
3759
...Repeated for PTP Port 2
375C
...Repeated for PTP Port 3
Real Time Clock Synchronizing Actual Values (Read Only)
375F
RTC Sync Source
0 to 5
---
1
F624
0 (None)
3760
PTP GrandMaster ID
0 to 100
--
1
F073
0
3764
Real Time Clock Accuracy
0 to 999999999
ns
1
F003
0
3766
PTP Port 1 State (3 items)
0 to 4
--
1
F625
0 (Disabled)
3769
RTC Offset
0 to 999999999
ns
1
F004
0
376B
PTP - IRIG-B Delta
-500000000 to 500000000
ns
1
F004
0
Real Time Clock Synchronizing FlexAnalogs (Read Only)
376D
PTP - IRIG-B Delta FlexAnalog
-262143 to 262143
---
1
F004
0
Field Units (Read/Write Setting) (8 modules)
3800
Field Unit 1 ID
0 to 1
---
1
F205
"U1"
3806
Field Unit 1 Function
0 to 1
---
1
F102
0 (Disabled)
3807
Field Unit 1 Type
0 to 3
---
1
F243
0 (CC-05)
Table B–10: MODBUS MEMORY MAP (Sheet 17 of 66)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for C60
Page 10: ...x C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 420: ...5 284 C60 Breaker Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 466: ...8 4 C60 Breaker Protection System GE Multilin 8 1 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 478: ...9 12 C60 Breaker Protection System GE Multilin 9 6 DISPOSAL 9 MAINTENANCE 9 ...
Page 492: ...A 14 C60 Breaker Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 648: ...E 10 C60 Breaker Protection System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Page 660: ...F 12 C60 Breaker Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 670: ...H 8 C60 Breaker Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 672: ...H 10 C60 Breaker Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 682: ...x C60 Breaker Protection System GE Multilin INDEX ...