The digital state can be entered locally (by directly pressing the front panel pushbutton) or remotely (via FlexLogic
operands) into FlexLogic equations, protection elements, and control elements. Typical applications include
breaker control, autorecloser blocking, and setting groups changes. The user-programmable pushbuttons are
under the control level of password protection.
The figure shows user-configurable pushbuttons for the enhanced front panel.
Figure 5–14: USER-PROGRAMMABLE PUSHBUTTONS (ENHANCED FRONT PANEL
The following figure shows user-configurable pushbuttons for the standard front panel.
Figure 5–15: USER-PROGRAMMABLE PUSHBUTTONS (STANDARD FRONT PANEL)
Both the standard and enhanced front panel pushbuttons can be custom labeled with a factory-provided template, available
online at
http://www.gegridsolutions.com/multilin
. The EnerVista software can also be used to create labels for the
enhanced front panel.
Each pushbutton asserts its own “On” and “Off” FlexLogic operands (for example,
PUSHBUTTON 1 ON
and
PUSHBUTTON 1
OFF
). These operands are available for each pushbutton and are used to program specific actions. If any pushbutton is
active, the
ANY PB ON
operand is asserted.
Each pushbutton has an associated LED indicator. By default, this indicator displays the present status of the correspond-
ing pushbutton (on or off). However, each LED indicator can be assigned to any FlexLogic operand through the
PUSHBTN 1
LED CTL
setting.
The activation and deactivation of user-programmable pushbuttons depends on whether latched or self-reset mode is pro-
grammed.
•
Latched mode
: In latched mode, a pushbutton can be set (activated) by asserting the operand assigned to the
PUSH-
BTN 1 SET
setting or by directly pressing the associated front panel pushbutton. The state of each pushbutton is stored
in non-volatile memory and maintained through a loss of control power.
The pushbutton is reset (deactivated) in latched mode by asserting the operand assigned to the
PUSHBTN 1 RESET
set-
ting or by directly pressing the associated active front panel pushbutton.
It can also be programmed to reset automatically through the
PUSHBTN 1 AUTORST
and
PUSHBTN 1 AUTORST DELAY
set-
tings. These settings enable the autoreset timer and specify the associated time delay. The autoreset timer can be
used in select-before-operate (SBO) breaker control applications, where the command type (close/open) or breaker
location (feeder number) must be selected prior to command execution. The selection must reset automatically if con-
trol is not executed within a specified time period.
•
Self-reset mode
: In self-reset mode, a user-programmable pushbutton can be set (activated) by asserting the operand
assigned to the
PUSHBTN 1 SET
setting or by pressing the front panel pushbutton. A pushbutton remains active for the
time it is pressed plus the dropout time specified in the
PUSHBTN 1 DROP-OUT TIME
setting. If the pushbutton is activated
via FlexLogic, the pulse duration is specified by the
PUSHBTN 1 DROP-OUT TIME
only. The time the operand remains
assigned to the
PUSHBTN 1 SET
setting remains On has no effect on the pulse duration.
842814A1.CDR
USER
LABEL 1
USER
LABEL 2
USER
LABEL 3
USER
LABEL 4
USER
LABEL 5
USER
LABEL 6
USER
LABEL 7
USER
LABEL 8
USER
LABEL 9
USER
LABEL 10
USER
LABEL 11
USER
LABEL 12
USER
LABEL 13
USER
LABEL 14
USER
LABEL 15
USER
LABEL 16
USER LABEL
USER LABEL
USER LABEL
USER LABEL
USER LABEL
USER LABEL
7
9
11
8
10
12
USER LABEL
1
3
5
2
4
6
USER LABEL
USER LABEL
USER LABEL
USER LABEL
USER LABEL
842779A1.cdr
Summary of Contents for C60
Page 10: ...x C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 420: ...5 284 C60 Breaker Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 466: ...8 4 C60 Breaker Protection System GE Multilin 8 1 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 478: ...9 12 C60 Breaker Protection System GE Multilin 9 6 DISPOSAL 9 MAINTENANCE 9 ...
Page 492: ...A 14 C60 Breaker Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 648: ...E 10 C60 Breaker Protection System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Page 660: ...F 12 C60 Breaker Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 670: ...H 8 C60 Breaker Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 672: ...H 10 C60 Breaker Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 682: ...x C60 Breaker Protection System GE Multilin INDEX ...