GE Multilin
C60 Breaker Protection System
A-7
APPENDIX A
A.1 PARAMETER LISTS
A
7284
SRC 4 Sb
VA
Source 4 phase B apparent power
7286
SRC 4 Sc
VA
Source 4 phase C apparent power
7288
SRC 4 PF
---
Source 4 three-phase power factor
7289
SRC 4 Phase A PF
---
Source 4 phase A power factor
7290
SRC 4 Phase B PF
---
Source 4 phase B power factor
7291
SRC 4 Phase C PF
---
Source 4 phase C power factor
7424
SRC 1 Pos Watthour
kWh
Source 1 positive Watthour
7426
SRC 1 Neg Watthour
Wh
Source 1 negative Watthour
7428
SRC 1 Pos varh
varh
Source 1 positive varhour
7430
SRC 1 Neg varh
varh
Source 1 negative varhour
7440
SRC 2 Pos Watthour
kWh
Source 2 positive Watthour
7442
SRC 2 Neg Watthour
Wh
Source 2 negative Watthour
7444
SRC 2 Pos varh
varh
Source 2 positive varhour
7446
SRC 2 Neg varh
varh
Source 2 negative varhour
7456
SRC 3 Pos Watthour
kWh
Source 3 positive Watthour
7458
SRC 3 Neg Watthour
kWh
Source 3 negative Watthour
7460
SRC 3 Pos varh
varh
Source 3 positive varhour
7462
SRC 3 Neg varh
varh
Source 3 negative varhour
7472
SRC 4 Pos Watthour
Wh
Source 4 positive Watthour
7474
SRC 4 Neg Watthour
Wh
Source 4 negative Watthour
7476
SRC 4 Pos varh
varh
Source 4 positive varhour
7478
SRC 4 Neg varh
varh
Source 4 negative varhour
7552
SRC 1 Frequency
Hz
Source 1 frequency
7554
SRC 2 Frequency
Hz
Source 2 frequency
7556
SRC 3 Frequency
Hz
Source 3 frequency
7558
SRC 4 Frequency
Hz
Source 4 frequency
7680
SRC 1 Demand Ia
Amps
Source 1 phase A current demand
7682
SRC 1 Demand Ib
Amps
Source 1 phase B current demand
7684
SRC 1 Demand Ic
Amps
Source 1 phase C current demand
7686
SRC 1 Demand Watt
Watts
Source 1 real power demand
7688
SRC 1 Demand var
Vars
Source 1 reactive power demand
7690
SRC 1 Demand Va
VA
Source 1 apparent power demand
7696
SRC 2 Demand Ia
Amps
Source 2 phase A current demand
7698
SRC 2 Demand Ib
Amps
Source 2 phase B current demand
7700
SRC 2 Demand Ic
Amps
Source 2 phase C current demand
7702
SRC 2 Demand Watt
Watts
Source 2 real power demand
7704
SRC 2 Demand var
Vars
Source 2 reactive power demand
7706
SRC 2 Demand Va
VA
Source 2 apparent power demand
7712
SRC 3 Demand Ia
Amps
Source 3 phase A current demand
7714
SRC 3 Demand Ib
Amps
Source 3 phase B current demand
7716
SRC 3 Demand Ic
Amps
Source 3 phase C current demand
7718
SRC 3 Demand Watt
Watts
Source 3 real power demand
7720
SRC 3 Demand var
Vars
Source 3 reactive power demand
7722
SRC 3 Demand Va
VA
Source 3 apparent power demand
7728
SRC 4 Demand Ia
Amps
Source 4 phase A current demand
7730
SRC 4 Demand Ib
Amps
Source 4 phase B current demand
7732
SRC 4 Demand Ic
Amps
Source 4 phase C current demand
Table A–1: FLEXANALOG DATA ITEMS (Sheet 7 of 13)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for C60
Page 10: ...x C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 420: ...5 284 C60 Breaker Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 466: ...8 4 C60 Breaker Protection System GE Multilin 8 1 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 478: ...9 12 C60 Breaker Protection System GE Multilin 9 6 DISPOSAL 9 MAINTENANCE 9 ...
Page 492: ...A 14 C60 Breaker Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 648: ...E 10 C60 Breaker Protection System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Page 660: ...F 12 C60 Breaker Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 670: ...H 8 C60 Breaker Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 672: ...H 10 C60 Breaker Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 682: ...x C60 Breaker Protection System GE Multilin INDEX ...