GE Multilin
C60 Breaker Protection System
B-57
APPENDIX B
B.4 MEMORY MAPPING
B
B39A
...Repeated for module number 15
B39D
...Repeated for module number 16
B3A0
...Repeated for module number 17
B3A3
...Repeated for module number 18
B3A6
...Repeated for module number 19
B3A9
...Repeated for module number 20
B3AC
...Repeated for module number 21
B3AF
...Repeated for module number 22
B3B2
...Repeated for module number 23
B3B5
...Repeated for module number 24
IEC 61850 XSWI Configuration (Read/Write Command) (24 modules)
B372
Command to Clear XSWI OpCnt (Operation Counter)
0 to 1
---
1
F126
0 (No)
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
B400
Number of Status Indications in GGIO1
8 to 128
---
8
F001
8
B402
IEC 61850 GGIO1 Indication FlexLogic operands (128
items)
0 to 4294967295
---
1
F300
0
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0
IEC 61850 Configurable GOOSE Function (GoEna)
0 to 1
---
1
F102
1 (Enabled)
B5A1
IEC 61850 Configurable GOOSE ID
---
---
---
F209
“GOOSEOut_x_”
B5C2
Configurable GOOSE Destination MAC Address
---
---
---
F072
0
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit Priority
0 to 7
---
1
F001
4
B5C6
IEC 61850 Configurable GOOSE VLAN ID
0 to 4095
---
1
F001
0
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
0 to 16383
---
1
F001
0
B5C8
IEC 61850 Configurable GOOSE ConfRev (Configuration
Revision)
1 to 4294967295
---
1
F003
1
B5CA
IEC 61850 Configurable GOOSE Retransmission Curve
0 to 3
---
1
F611
3 (Relaxed)
B5CB
Configurable GOOSE Dataset Items for Transmission
(64 items)
0 to 1008
---
1
F616
0 (None)
B60B
...Repeated for module number 2
B676
...Repeated for module number 3
B6E1
...Repeated for module number 4
B74C
...Repeated for module number 5
B7B7
...Repeated for module number 6
B822
...Repeated for module number 7
B88D
...Repeated for module number 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 modules)
B900
Configurable GOOSE Dataset Items for Reception
(32 items)
0 to 197
---
1
F233
0 (None)
B920
...Repeated for module number 2
B940
...Repeated for module number 3
B960
...Repeated for module number 4
B980
...Repeated for module number 5
B9A0
...Repeated for module number 6
B9C0
...Repeated for module number 7
B9E0
...Repeated for module number 8
BA00
...Repeated for module number 9
BA20
...Repeated for module number 10
BA40
...Repeated for module number 11
BA60
...Repeated for module number 12
BA80
...Repeated for module number 13
BAA0
...Repeated for module number 14
BAC0
...Repeated for module number 15
BAE0
...Repeated for module number 16
Contact Inputs (Read/Write Setting) (96 modules)
BB00
Contact Input 1 Name
---
---
---
F205
“Cont Ip 1“
Table B–10: MODBUS MEMORY MAP (Sheet 49 of 66)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for C60
Page 10: ...x C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 420: ...5 284 C60 Breaker Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 466: ...8 4 C60 Breaker Protection System GE Multilin 8 1 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 478: ...9 12 C60 Breaker Protection System GE Multilin 9 6 DISPOSAL 9 MAINTENANCE 9 ...
Page 492: ...A 14 C60 Breaker Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 648: ...E 10 C60 Breaker Protection System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Page 660: ...F 12 C60 Breaker Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 670: ...H 8 C60 Breaker Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 672: ...H 10 C60 Breaker Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 682: ...x C60 Breaker Protection System GE Multilin INDEX ...