6208
SRC 2 Ia RMS
Amps
Source 2 phase A current RMS
6210
SRC 2 Ib RMS
Amps
Source 2 phase B current RMS
6212
SRC 2 Ic RMS
Amps
Source 2 phase C current RMS
6214
SRC 2 In RMS
Amps
Source 2 neutral current RMS
6216
SRC 2 Ia Mag
Amps
Source 2 phase A current magnitude
6218
SRC 2 Ia Angle
Degrees
Source 2 phase A current angle
6219
SRC 2 Ib Mag
Amps
Source 2 phase B current magnitude
6221
SRC 2 Ib Angle
Degrees
Source 2 phase B current angle
6222
SRC 2 Ic Mag
Amps
Source 2 phase C current magnitude
6224
SRC 2 Ic Angle
Degrees
Source 2 phase C current angle
6225
SRC 2 In Mag
Amps
Source 2 neutral current magnitude
6227
SRC 2 In Angle
Degrees
Source 2 neutral current angle
6228
SRC 2 Ig RMS
Amps
Source 2 ground current RMS
6230
SRC 2 Ig Mag
Amps
Source 2 ground current magnitude
6232
SRC 2 Ig Angle
Degrees
Source 2 ground current angle
6233
SRC 2 I_0 Mag
Amps
Source 2 zero-sequence current magnitude
6235
SRC 2 I_0 Angle
Degrees
Source 2 zero-sequence current angle
6236
SRC 2 I_1 Mag
Amps
Source 2 positive-sequence current magnitude
6238
SRC 2 I_1 Angle
Degrees
Source 2 positive-sequence current angle
6239
SRC 2 I_2 Mag
Amps
Source 2 negative-sequence current magnitude
6241
SRC 2 I_2 Angle
Degrees
Source 2 negative-sequence current angle
6242
SRC 2 Igd Mag
Amps
Source 2 differential ground current magnitude
6244
SRC 2 Igd Angle
Degrees
Source 2 differential ground current angle
6272
SRC 3 Ia RMS
Amps
Source 3 phase A current RMS
6274
SRC 3 Ib RMS
Amps
Source 3 phase B current RMS
6276
SRC 3 Ic RMS
Amps
Source 3 phase C current RMS
6278
SRC 3 In RMS
Amps
Source 3 neutral current RMS
6280
SRC 3 Ia Mag
Amps
Source 3 phase A current magnitude
6282
SRC 3 Ia Angle
Degrees
Source 3 phase A current angle
6283
SRC 3 Ib Mag
Amps
Source 3 phase B current magnitude
6285
SRC 3 Ib Angle
Degrees
Source 3 phase B current angle
6286
SRC 3 Ic Mag
Amps
Source 3 phase C current magnitude
6288
SRC 3 Ic Angle
Degrees
Source 3 phase C current angle
6289
SRC 3 In Mag
Amps
Source 3 neutral current magnitude
6291
SRC 3 In Angle
Degrees
Source 3 neutral current angle
6292
SRC 3 Ig RMS
Amps
Source 3 ground current RMS
6294
SRC 3 Ig Mag
Amps
Source 3 ground current magnitude
6296
SRC 3 Ig Angle
Degrees
Source 3 ground current angle
6297
SRC 3 I_0 Mag
Amps
Source 3 zero-sequence current magnitude
6299
SRC 3 I_0 Angle
Degrees
Source 3 zero-sequence current angle
6300
SRC 3 I_1 Mag
Amps
Source 3 positive-sequence current magnitude
6302
SRC 3 I_1 Angle
Degrees
Source 3 positive-sequence current angle
6303
SRC 3 I_2 Mag
Amps
Source 3 negative-sequence current magnitude
6305
SRC 3 I_2 Angle
Degrees
Source 3 negative-sequence current angle
6306
SRC 3 Igd Mag
Amps
Source 3 differential ground current magnitude
6308
SRC 3 Igd Angle
Degrees
Source 3 differential ground current angle
6336
SRC 4 Ia RMS
Amps
Source 4 phase A current RMS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 2 of 13)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for C60
Page 10: ...x C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 420: ...5 284 C60 Breaker Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 466: ...8 4 C60 Breaker Protection System GE Multilin 8 1 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 478: ...9 12 C60 Breaker Protection System GE Multilin 9 6 DISPOSAL 9 MAINTENANCE 9 ...
Page 492: ...A 14 C60 Breaker Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 648: ...E 10 C60 Breaker Protection System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Page 660: ...F 12 C60 Breaker Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 670: ...H 8 C60 Breaker Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 672: ...H 10 C60 Breaker Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 682: ...x C60 Breaker Protection System GE Multilin INDEX ...