showstatus(8)
488
SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised September 2008
module in a CPU memory unit are degraded because of an error.
EXAMPLE 2
Displays the degraded units. In this example, a memory module on a memory
board is degraded because of an error.
EXAMPLE 3
Displays the degraded units. In this example, a CPU/memory board unit and
memory module on a motherboard unit are degraded because of an error.
EXAMPLE 4
Displays the degraded units. In this example, a CPU/memory board unit is
degraded because a crossbar unit is degraded.
EXIT STATUS
The following exit values are returned:
XSCF>
showstatus
CMU#0;
* CPUM#0-CHIP#0 Status:Faulted;
* MEM#00A Status:Faulted;
XSCF>
showstatus
MBU_B;
MEMB#0;
* MEM#0A Status:Faulted;
XSCF>
showstatus
MBU_B Status:Normal;
* MEMB#1 Status:Deconfigured;
* MEM#3B Status:Deconfigured;
XSCF>
showstatus
MBU_B Status:Normal;
* CPUM#1-CHIP#1 Status:Deconfigured;
* XBU_B#0 Status:Degraded;
0
Successful completion.
>0
An error occurred.
Summary of Contents for SPARC Enterprise M3000
Page 1: ......
Page 2: ......
Page 6: ......
Page 12: ......
Page 24: ...xviii SPARC Enterprise Mx000 Servers XSCF Reference Manual July 2010 ...
Page 32: ...Intro 8 8 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised July 2010 ...
Page 36: ...addboard 8 12 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised August 2009 ...
Page 42: ...addfru 8 18 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised September 2008 ...
Page 60: ...clockboard 8 36 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised April 2010 ...
Page 82: ...dumpconfig 8 58 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised August 2009 ...
Page 86: ...exit 1 62 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised January 2007 ...
Page 142: ...poweron 8 118 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised August 2009 ...
Page 154: ...reset 8 130 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised August 2009 ...
Page 172: ...sendbreak 8 148 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised August 2009 ...
Page 180: ...setad 8 156 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised February 2010 ...
Page 198: ...setcod 8 174 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised July 2010 ...
Page 202: ...setdate 8 178 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised February 2010 ...
Page 208: ...setdcl 8 184 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised September 2008 ...
Page 296: ...setroute 8 272 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised April 2010 ...
Page 302: ...setsmtp 8 278 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised August 2009 ...
Page 322: ...setssh 8 298 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised August 2009 ...
Page 346: ...showad 8 322 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised November 2009 ...
Page 444: ...showlocale 8 420 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised March 2008 ...
Page 482: ...showntp 8 458 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised November 2009 ...
Page 502: ...showsnmp 8 478 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised January 2007 ...
Page 510: ...showssh 8 486 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised August 2009 ...
Page 558: ...who 1 534 SPARC Enterprise Mx000 Servers XSCF Reference Manual Last Revised January 2007 ...
Page 559: ......
Page 560: ......