![Festo CMMD-AS series Description Download Page 76](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_description_2283098076.webp)
4
Dimension reference system
76
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
4.1.2
Measuring system for rotative drives
Example: Homing method “current position”
REF
AZ
a
b
e
PZ
d
1
2
M
Turn positive (+)
Turn negative (–)
c
TP/AP
SLP
SLN
LSN
LSP
REF
Homing point (reference point)
1)
AZ
Axis zero point
1)
PZ
Project zero point
SLN
Negative software end position (SW limit negative)
SLP
Positive software end position (SW limit positive)
LSN
Limit switch (hardware) negative (Limit switch negative)
1)
LSP
Limit switch (hardware) positive (Limit switch positive)
1)
SP
Target position
AP
Actual position
1)
a
Offset “axis zero point (AZ)”
b
Offset “project zero point (PZ)”
c
Offset “target/actual position (TP/AP)”
d
Optional: Offset “Software end position negative (SLN)”
2)
e
Optional: Offset “Software end position positive (SLP)”
2)
1
Effective positioning range
2
Working positioning range (no hardware limit switches)
1)
Additional information
page 161.
2)
In the “Endless positioning” operational function, no limit switch can be parameterised.
Tab. 4.2
Measuring system for rotative drives
Additional information
CD-ROM: Documentation “CMMS-AS_de.pdf/CMMS-ST_de.pdf/
CMMD-AS_de.pdf ” or the Festo Configuration Tool (FCT): Dynamic/static plug-in help.
Summary of Contents for CMMD-AS series
Page 245: ......