6
Positioning mode
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
135
Parameter: Start condition “Interrupt”
The diagram shows the course for the parameter “Start condition: Interrupt”.
Position 1
t
t
t
Motion complete
(DOUT1)[X1.12]
Start positioning
Start record sequence
(DIN8)[X1.23]
1
2
Position 2
Start “Positioning record 2” via the
start condition “Interrupt”
Start “Positioning
record 1”
Parameter
Description
Start condition
–
Interrupt:
The current positioning record is interrupted and the next record is
started immediately.
Note:
The error message “E421” is generated if the new setpoint position
cannot be approached from the current drive status (actual posi-
tion value, actual speed value) (e.g. if the new position cannot be
approached with the parameterised delay due to the current travel
speed).
Tab. 6.13 Parameter: Start condition “Interrupt”