![Festo CMMD-AS series Description Download Page 75](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_description_2283098075.webp)
4
Dimension reference system
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
75
4
Measuring system
4.1
Measuring system for electrical drives
4.1.1
Measuring system for linear drives
Example: Homing method “limit switch”, negative direction
REF
AZ
a
b
c
PZ
d
e
TP/AP
SLP
SLN
Run positive (+)
LSN
LSP
Run negative (–)
M
1
2
REF
Homing point (reference point)
1)
AZ
Axis zero point
1)
PZ
Project zero point
SLN
Negative software end position (SW limit negative)
SLP
Positive software end position (SW limit positive)
LSN
Limit switch (hardware) negative (Limit switch negative)
1)
LSP
Limit switch (hardware) positive (Limit switch positive)
1)
SP
Target position
AP
Actual position1)
a
Offset “axis zero point (AZ)”
b
Offset “project zero point (PZ)”
c
Offset “target/actual position (TP/AP)”
d
Offset “Software end position negative (SLN)”
e
Offset “Software end position positive (SLP)”
1
Effective stroke
2
Working stroke (no hardware limit switches)
1)
Additional information
page 161.
Tab. 4.1
Measuring system for linear drives
Additional information
CD-ROM: Documentation “CMMS-AS_de.pdf/CMMS-ST_de.pdf/CMMD-
AS_de.pdf ” or the Festo Configuration Tool (FCT): Dynamic/static plug-in help.