![Festo CMMD-AS series Description Download Page 218](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_description_2283098218.webp)
A
Diagnostic messages
218
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
Error group 04
Temperature monitoring, electronics
No.
Code
Message
Reaction
04-0
4210h
Excess/low temperature of power electronics
configurable
Cause
Motor controller is overheated.
–
Motor controller overloaded?
–
Temperature display plausible?
Action
•
Check installation conditions, cooling through the housing
surface, integrated heat sink and back wall.
•
Check the drive layout (due to possible overloading in continu-
ous operation).
Error group 05
Internal power supply
No.
Code
Message
Reaction
05-0
5114h
5 V electronics supply fault
PS off
Cause
Monitoring of the internal power supply has recognised under-
voltage. This is either due to an internal defect or an overload/
short circuit caused by connected peripherals.
Action
•
Separate device from the entire peripheral equipment and
check whether the error is still present after reset. If so, an
internal defect is present
Repair by the manufacturer.
05-1
5115h
Error in 24 V supply
PS off
Cause
Monitoring of the internal power supply has recognised under-
voltage.
Action
•
Check 24 V logic supply.
•
Separate device from the entire peripheral equipment and
check whether the error is still present after reset. If so, an
internal defect is present
Repair by the manufacturer.
05-2
5116h
12 V electronics supply fault
PS off
Cause
CMMS-ST only:
Monitoring of the internal power supply has recognised under-
voltage. This is either due to an internal defect or an overload/
short circuit caused by connected peripherals.
Action
•
Separate device from the entire peripheral equipment and
check whether the error is still present after reset. If so, an
internal defect is present
Repair by the manufacturer.
05-2
8000h
Driver supply error/driver supply failed
PS off
Cause
Only CMMS-AS/CMMD-AS:
Error in the plausibility check of the driver supply (safe torque off )
Action
•
Separate device from the entire peripheral equipment and
check whether the error is still present after reset. If so, an
internal defect is present
Repair by the manufacturer.
Summary of Contents for CMMD-AS series