![Festo CMMD-AS series Description Download Page 202](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_description_2283098202.webp)
9
Operational functions
202
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
9.3
Analogue monitor
9.3.1
Function: Analogue monitor
Through the analogue monitor (AMON0)[X1.17], the motor controller can provide various setpoint/ac-
tual values, for example, to a controller or oscilloscope as an analogue output signal.
Output analogue monitor through digital output
CMMS/CMMD
Analogue output
Analogue monitor
Control section
X1
X1.1
X1.2
Monitor signal:
0…10 V
Setpoint/actual values:
–
Speed
–
Position
–
Current
–
….
Fig. 9.5
Overview: Output analogue monitor through digital output
9.3.2
Connection: Analogue output
The connection diagram shows the analogue output for the analogue monitor.
CMMS/CMMD
14
Analogue load “Analogue monitor” (AGND)
Analogue monitor (AMON)
X1/X1.1/X1.2
17
1
Screening (SGND)
Fig. 9.6
Connection: Analogue output