Control interfaces
50
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
3.2.3
Digital input/output signals as a function of the operating mode/mode
Designa-
tion
Pin
[X1.x]
[X1.1.x]
[X1.2.x]
Mode 0
Individual record
Mode 1
Mode 2
Record linking
Mode 3
Synchronisation
Jogging
Teaching
24 V DC
[18]
Supply voltage 24 V DC (output)
1)
GND 24 V
[6]
Load “DIN/DOUT”
DIN 0
[19]
Record selection bit 0
–
DIN 1
[7]
Record selection bit 1
–
DIN 2
[20]
Record selection bit 2
CLK/CW_24
DIN 3
[8]
Record selection bit 3
Halt record
sequence
DIR/CCW_24
DIN 4
[21]
Output stage enable
DIN 5
[9]
Controller enable
DIN 6
[22]
Limit switch 0
DIN 7
[10]
Limit switch 1
DIN 8
[23]
Start positioning
–
Teach
Start record
sequence
Start
synchronisation
DIN 9
2)
(Sample)
[11]
Mode bit 1 = 0
Mode bit 1 = 1
DIN 10
[3]
Record selection
bit 4
Jog+
Record
selection
bit 4
NEXT1
–
DIN 11
[16]
Record selection
bit 5
Jog–
Record
selection
bit 5
NEXT2
–
DIN 12
3)
(AIN0)
[2]
Mode bit 0 = 0
Mode bit 0 = 1
Mode bit 0 = 0
Mode bit 0 = 1
DIN 13
3)
(#AIN0)
[15]
Stop
DOUT0
[24]
Controller ready for operation
DOUT1
[12]
Motion complete (MC)
4)
Standstill
reached
DOUT2
[25]
Start confirmed
4)
–
Teach
confirmed
Start confirmed
4)
Position
synchronous
DOUT3
[13]
Common error
4)
1)
Internally connected with power supply “24 V DC” (input) at the connection [X9.6].
2)
The digital input (DIN9) is used as a sample input with flying measurement.
3)
The digital inputs (DIN12/DIN13) are used as analogue inputs (AIN0/#AIN0) in speed, force or torque mode.
4)
The digital output can be freely configured (default setting in the Festo Configuration Tool (FCT)).
Tab. 3.2
Overview: Digital I/O modules dependent on the operating mode/mode