Configure endless positioning in the Festo Configuration Tool (FCT)
To be able to use the “Endless positioning” function, the following settings must be taken into account
in configuration of the linear axis/axis of rotation in the Festo Configuration Tool (FCT).
1. Mark either the option field
“Rotative Festo axis”, “Linear
user-defined axis” or “Rotative
user-defined axis” in the drive
configuration.
2. Activate the “Unlimited” control
field for endless positioning.
1
2
Fig. 9.9
Configure endless positioning in the Festo Configuration Tool (FCT)
For endless positioning, only the relative positioning types “RA/RN” can be used (position
record list parameter “Mode”
page 128).
The minimum or maximum absolute position is always used as a target in the jog mode.
For this reason, endless positioning is not possible.
The connected limit switches are only active during homing.