3
Control interfaces
52
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
3.2.4
Digital input signals
The digital input signals are permanently assigned to the digital inputs (DIN0…13). The function is de-
pendent on the selected operating mode/mode of the control interface “digital inputs/outputs”
page 50.
Signal
Description
Signal
General operating signals
Enable Power
(DIN4)
[X1.21]/[X1.1.21/X1.2.21]
–
High signal for release of the output stage (motor
energised)
page 101.
–
Low signal for immediate blocking of the output stage
•
The category 0 STOP function, EN 60204-1 can be
realised in combination with an external safety
switching device
description “Safety
function STO”,
–
GDCP-CMMS-AS-G2-S1-...
–
GDCP-CMMS-ST-G2-S1-...
–
GDCP-CMMD-AS-S1-....
•
Functional timing diagram of the input
page 107.
high
active
Enable Control
(DIN5)
[X1.9]/[X1.1.9/X1.2.9]
–
High signal for release of the controller
page 101.
–
Low signal for blocking the controller enable function;
results in controlled braking of the motor
•
The category 1 STOP function, EN 60204-1 can be
realised in combination with an external safety
switching device
description “Safety
function STO”,
–
GDCP-CMMS-AS-G2-S1-...
–
GDCP-CMMS-ST-G2-S1-...
–
GDCP-CMMD-AS-S1-....
•
Functional timing diagram of the input
page 108.
–
Low signal for acknowledgement of error messages
page 214.
high
active
Stop
(DIN13)
[X1.15]/[X1.1.15/X1.2.15]
Low signal for controlled stopping of the current
movement
•
The category 2 STOP function, EN 60204-1 can be
realised in combination with an external safety
switching device for standstill monitoring.
•
Functional timing diagram for
–
Individual record operation
page 123
–
Record linking operation
page 141
–
Homing mode
page 159
low active
Summary of Contents for CMMD-AS series
Page 245: ......