6.5.3
Timing diagram: Start/cancel individual record
Timing diagram: Start individual record via Start positioning signal
The timing diagram shows the starting of the individual record via the Start positioning signal (DIN8).
Start positioning
(DIN8)[X1.23]
Stop
(DIN13)[X1.15]
Motion complete
(DOUT1)[X1.12]
Controller ready for operation
(DOUT0)[X1.24]
Confirm start
(DOUT2)[X1.25]
Common error
(DOUT3)[X1.13]
Speed
t3
Record selection bit 0…5
(Positioning record 1…63)
(DIN…)[X1.…]
t2
t3
t4
t1
t1
≤
2.5 ms
t2
≥
2.5 ms
t3
≤
5 ms
t4
= … ms (FCT: Dependent on the parameters
“Message window” and “Damping time” in
the message “Destination reached”)
Fig. 6.7
Timing diagram: Start individual record via start positioning signal