6
Positioning mode
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
133
Parameter: Start condition
One of the conditions “Ignore/delay/interrupt” can be configured for the start of the new positioning
record via the “Start condition” parameter.
Parameter: Start condition “Ignore”
The diagram shows the course for the parameter “Start condition: Ignore”.
t
t
t
Motion complete
(DOUT1)[X1.12]
Start positioning
Start record sequence
(DIN8)[X1.23]
Item 1
1
2
Start “Positioning
record 1”
Parameter
Description
Start condition
–
Ignore:
Other start signals do not have any effect when executing the cur-
rent positioning record. The current positioning record moves to
parameterised position 1. After reaching the position the next posi-
tioning record can be started.
Tab. 6.11 Parameter: Start condition “Ignore”
Summary of Contents for CMMD-AS series
Page 245: ......