![Festo CMMD-AS series Description Download Page 140](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_description_2283098140.webp)
6
Positioning mode
140
Festo – GDCP-CMMS/D-FW-EN – 1404NH – English
Timing diagram: Interrupting the record sequence via the halt record sequence signal
The timing diagram shows the interruption and continuation of the record sequence via the halt record
sequence signal (DIN3).
Start record sequence
(DIN8)[X1.23]
Stop
(DIN13)[X1.15]
Halt record sequence
(DIN3)[X1.8]
Motion complete
(DOUT1)[X1.12]
Controller ready for operation
(DOUT0)[X1.24]
Confirm start
(DOUT2)[X1.25]
Common error
(DOUT3)[X1.13]
Speed
(Positioning record 1/2/3)
t2
1
Record selection bit 0…2
(Positioning record 1…7)
(DIN…)[X1.…]
t3
t1
t2
t3
t7
2
3
t6
t6
t5
t5
2
3
t4
t4
t1
≥
2.5 ms
t2
≤
5 ms
t3
L
16 ms
t4
≤
2.5 ms
t5
= … ms (FCT: Dependent on the deceleration
ramp)
t6
= … ms (FCT: Dependent on the acceleration
ramp)
t7
= … ms (FCT: Dependent on the parameters
“Message window” and “Damping time” in
the message “Destination reached”)
Fig. 6.15 Timing diagram: Interrupting the record sequence via the halt record sequence signal
Summary of Contents for CMMD-AS series