Falcon 4M Camera Manual
Teledyne DALSA
03-032-20044-03
81
Command
Syntax Parameters
Description
get p rnu coefficient
gpc
xy
Read the PRN U coefficient at ad d ress
xy, w here xy falls in the range from 1, 1
to 2352, 1728.
get com m and
p aram eter
get
s
Disp lay valu e of cam era com m and
s
get sync frequ ency
gsf
m
Disp lay the frequ ency and H IGH tim e
of CC1-CC4.
1
: Cam era Link inp u t (CC1)
4
: Cam era Link inp u t (CC4)
help
h
Disp lay the online help
load p ixel
coefficients
lpc
Load s the p reviou sly saved p ixel
coefficients from non -volatile m em ory
d eterm ined by the
csn
valu e.
0-2
= Factory calibrated coefficients
3-5
= User coefficient sets
reset cam era
rc
Reset the entire cam era (reboot).
restore factory
settings
rfs
Restore the camera‘s factory settings.
N ote: this d oes N OT restore factory
FFC coefficients (u se
lpc
for this).
reset p ixel
coefficients
rpc
Resets the FPN and PRN U coefficients
to 0/ 1 resp ectively.
restore u ser
settings
rus
Restore the camera‘s last saved user
settings. N ote: this d oes N OT restore
FFC coefficients (u se
lpc
for this).
set analog offset
sao
t i
Set the analog offset.
t
= Tap selection. Allow able valu e is
0
for all tap s.
i
= Analog offset valu e. Allow able
range is
0
-
511
.
set bau d rate
sbr
m
Set the sp eed of the serial
com m u nication p ort. Bau d rates:
9600
,
19200
,
57600
, and
115200
. Defau lt
bau d : 9600
set d igital offset
sdo
t i
Used as a su bstitu te w hen no FPN
correction is p erform ed . N ot
recom m end ed in general.
t
= Tap selection. Allow able valu e is
0
for all tap s.
i
= Offset in the range from
0
to
1023
set exp osu re m od e
sem
m
Set the exp osu re m od e. Available
valu es are:
2
: Internal p rogram m able fram e rate
and exp osu re tim e u sing com m and s
ssf
and
set
4: Sm art EXSYN C, fram e rate and
exp osu re tim e controlled by CC1
(u ser EXSYN C)
6: Fram e rate controlled by CC1,
exp osu re tim e controlled by
set
Parameters:
t
= tap id
i
= integer value
f
= real number
s
= string
m
= member of a set