Falcon 4M Camera Manual
Teledyne DALSA
03-032-20044-03
29
4M60 Data Readout Configurations
Camera Link Mode Configuration (Controlled by clm
command)
Pixel Rate
Configuration
(Controlled by
sot
command)
Command
Camera Link
Configuration
Camera Link Taps Bit
Depth
clm 2
Base
2 Cam era Link tap s
w here:
1 = Tap s 1+3
2 = Tap s 2+4
8
sot 130
= 65
MH z strobe
sot 160
= 80
MH z strobe
clm 3
Base
2 Cam era Link tap s
w here:
1 = Tap s 1+3
2 = Tap s 2+4
10
sot 130
= 65
MH z strobe
sot 160
= 80
MH z strobe
clm 15
Med iu m
4 Cam era Link tap s
w here:
1 = Tap 1
2 = Tap 2
3 = Tap 3
4 = Tap 4
8
sot 260
= 65
MH z strobe
sot
320
= 80 MH z
strobe
clm 16
Med iu m
4 Cam era Link tap s
w here:
1 = Tap 1
2 = Tap 2
3 = Tap 3
4 = Tap 4
10
sot 260
= 65
MH z strobe
sot 320
= 80
MH z strobe
3.3.2 Setting the Camera Link Mode
Pu rp ose:
Sets the camera‘s Camera Link con figuration, number of Camera
Link tap s and d ata bit d ep th. Refer to the tables above for a
d escrip tion of each Cam era Link m od e.
Syntax:
clm
m
Syntax Elem ents:
m
Ou tp u t m od e to u se:
2
: Base configu ration, 2 tap s, 8 bit ou tp u t
3
: Base configu ration, 2 tap s, 10 bit ou tp u t
15
: Med iu m configu ration, 4 tap s, 8 bit ou tp u t (4M60 only)
16
: Med iu m configu ration, 4 tap s, 10 bit ou tp u t (4M60 only)
N otes:
To retrieve the cu rrent Cam era Link m od e, u se the
com m and
gcp
For d etails on line tim es and fram e read ou t tim es w hen
u sing a w ind ow of interest, refer to follow ing table.
Exam p le:
clm 3