Falcon 4M Camera Manual
03-032-20044-03
Teledyne DALSA
28
nu m ber of ou tp u t tap s, and bit d ep th. Using the
sot
com m and , you d eterm ine the
camera‘s output rate. These tw o commands w ork together to determine your final camera
ou tp u t configu ration.
4M30 Data Readout Configurations
Camera Link Mode Configuration
(Controlled by clm command)
Pixel Rate
Configuration
(Controlled by
sot
command)
Command
Camera Link
Configuration
Camera Link Taps Bit
Depth
clm 2
Base
2 Cam era Link tap s
w here:
1 = Tap s 1+3
2 = Tap s 2+4
8
sot 130
= 65
MH z strobe
sot 160
= 80
MH z strobe
clm 3
Base
2 Cam era Link tap s
w here:
1 = Tap s 1+3
2 = Tap s 2+4
10
sot 130
= 65
MH z strobe
sot 160
= 80
MH z strobe