Falcon 4M Camera Manual
03-032-20044-03
Teledyne DALSA
8
Operating Ranges
Notes
Satu ration Equ ivalent Exp osu re
55 typ nJ/ cm
2
N oise Equ ivalent Exp osu re
80 typ p J/ cm
2
Satu ration Ou tp u t Am p litu d e
1023 DN
Test conditions unless otherwise noted:
sem 2
(exp osu re m od e 2).
ssf 55
(55 fram es p er second rate).
set 2000
(2 m illisecond exp osu re tim e).
sem 2
(Exp osu re m od e 2) .
Fu ll fram e/ w ind ow .
clm 16
(4 tap , 10 bit).
sot 320
(80 MH z cam era link strobe).
efd 1
(Snap shot m od e 1).
snd 1
(N u m ber of fast fram e d u m p s = 1).
Light Sou rce: Broad band Qu artz H alogen, 3250K (3050 to 3450), w ith a 750 nm cu toff
filter .
Am bient test tem p eratu re 25°C.
Average ou tp u t 840 DN .
Flat field correction (FFC) tu rned on .
Notes:
1.
Measu red at the front p late.
2.
Based on ou tp u t at 1023 DN .
3.
Ou tp u t over 10-90%.
4.
Snap shot m od e 0 allow s for m arginally higher fram e rates.
5.
Op tical d istance.
6.
+12V consu m es the least am ou nt of p ow er .
7.
With FFC on. Resp onsivity is not calibrated w hen FCC is tu rned off.
8.
Measu red at half satu ration.