Falcon 4M Camera Manual
03-032-20044-03
Teledyne DALSA
20
Camera Link Connector Pinout
Medium Configuration
Base Configuration
Up to an additional 2 Channel Link Chips One Channel Link Chip + Camera
C Serial Communication
Camera
Connector
Right Angle
Frame Grabber
Connector
Channel Link
Signal
Camera
Connector
Right Angle
Frame
Grabber
Connector
Channel
Link Signal
1
1
inner shield
1
1
inner shield
14
14
inner shield
14
14
inner shield
2
25
Y0-
2
25
X0-
15
12
Y0+
15
12
X0+
3
24
Y1-
3
24
X1-
16
11
Y1+
16
11
X1+
4
23
Y2-
4
23
X2-
17
10
Y2+
17
10
X2+
5
22
Yclk-
5
22
Xclk-
18
9
Yclk+
18
9
Xclk+
6
21
Y3-
6
21
X3-
19
8
Y3+
19
8
X3+
7
20
100 ohm
7
20
SerTC+
20
7
term inated
20
7
SerTC-
8
19
Z0-
8
19
SerTFG-
21
6
Z0+
21
6
9
18
Z1-
9
18
CC1-
22
5
Z1+
22
5
CC1+
10
17
Z2-
10
17
CC2+
23
4
Z2+
23
4
CC2-
11
16
Zclk-
11
16
CC3-
24
3
Zclk+
24
3
CC3+
12
15
Z3-
12
15
CC4+
25
2
Z3+
25
2
CC4-
13
13
inner shield
13
13
inner shield
26
26
inner shield
26
26
inner shield
Notes:
*Exterior Overshield is connected to the shells of the connectors on both end s.
**3M p art 14X26-SZLB-XXX-0LC is a com p lete cable assem bly, inclu d ing connectors.
Unu sed p airs shou ld be term inated in 100 ohm s at both end s of the cable.
Inner shield is connected to signal grou nd insid e cam era
Camera Control Configuration
Signal
Configuration
CC1
EXSYN C
CC2
Reserved for fu tu re u se
CC3
Reserved for fu tu re u se
CC4
Wind ow toggle