Falcon 4M Camera Manual
03-032-20044-03
Teledyne DALSA
26
Retrieving Camera Settings
To retrieve current camera settings, use the command:
Syntax:
gcp
3.1 First Power Up Camera Settings
When the cam era is p ow ered u p for the first tim e, it op erates u sing the follow ing factory
settings:
PT-4x-04M60
Flat field coefficients enabled (calibrated in exp osu re m od e 2, 55 fp s, and an
exp osu re tim e of 2 m s [non-concu rrent read ou t and integration], snap shot m od e
1, nu m ber of fast fram e d u m p s = 1)
Exp osu re m od e 2
60 fp s
9995 µs exp osu re tim e
Cam era Link m od e 16 (Med iu m configu ration, 4 tap s. 10 bits)
80 MH z p ixel rate (320 MH z total throu ghp u t)
Fu ll w ind ow (2352 x 1728)
Snap shot m od e 1 enabled (EFD 1)
PT-2x-04M30
Flat field coefficients enabled (calibrated in exp osu re m od e 2, 29 fp s, and
exp osu re tim e of 2 m s [non-concu rrent read ou t and integration], snap shot m od e
1, nu m ber of fast fram e d u m p s = 1)
Exp osu re m od e 2
30 fp s
14992 µs exp osu re tim e
Cam era Link m od e 3 (Med iu m configu ration, 2 tap s. 10 bits)
80 MH z p ixel rate (160 total throu ghp u t)
Fu ll w ind ow (2352 x 1728)
Snap shot m od e 1 (EFD 1)