Test Results
266
MAX-800 Series
Performance Monitoring
Performance Monitoring
Note:
This tab is only available with Transport test applications with Pattern
client. Monitored performance parameters are reported, non-monitored
values are left blank.
The Performance Monitoring tab gives error performance events and
parameters for the circuit under test.
From the
Test
menu, tap
Results
, and the
Performance Monitoring
tab.
Each button on top of the window represents a level of the analyzed signal
for which the Performance Monitoring (PM) is available. Each button also
displays the PM standard(s) available for this level. Tap a signal level button
to get its PM results.
Note:
G.821 and M.2100 OOSM are only available when
No Pattern Analysis
(Live)
check box is cleared (refer to page
Standard’s availability
Analyzed Signal
G.821 G.826
ISM
G.828
ISM
G.829
ISM
M.2100
ISM
M.2100
OOSM
M.2101
ISM
DS3/DS1/E4/E3/E2/E1
X
X
Section/RS
X
Line/MS
X
X
VTn/STS-n/AU-n/ TU-n
X
X
BERT
X
X
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...