Test Functions
MaxTester
331
FEAC
FEAC
The Far-End Alarm and Control signal (FEAC) provides Communication
Channel capability over a DS3 in a network applications using C-bit Parity
configuration (see page 167).
From the test menu, tap
Functions
, and the
FEAC
tab.
Generated Messages
Allows configuring and sending alarms/status information and control
signals (loopback commands) to other network elements.
Alarm/Status and Unassigned
Codeword
allows the selection of the codeword alarm/status to be
generated either manually or continuously.
The FEAC message format is a 16 bit codeword
(0xxxxxx0 11111111) with the rightmost bit transmitted first. The
0xxxxxx0 represents the message codeword.
Mode
is the alarm/status injection mode:
Manual
or
Continuous
.
Codeword
DS3 Equipment Failure SA (00110010)
Single DS1 LOS (00111100)
User Defined (00100000)
DS3 Loss of Signal (LOS) (00011100)
DS1 Equipment Failure NSA
(00000110)
User Defined (00100010)
DS3 Out-of-Frame (00000000)
User Defined (00000010)
User Defined (00101000)
DS3 AIS Received (00101100)
User Defined (00000100)
User Defined (00101110)
DS3 Idle Signal Received (00110100)
User Defined (00001000)
User Defined (00110000)
DS3 Equipment Failure NSA (00011110)
User Defined (00001100)
User Defined (00111110)
DS3 NUI Loop Up (00010010)
User Defined (00010000)
User Defined (01000000)
DS3 NUI Loop Down (00100100)
User Defined (00010100)
User Defined (01111010)
Common Equipment Failure NSA (00111010) User Defined (00010110)
User Defined (01111100)
Multiple DS1 LOS (00101010)
User Defined (00011000)
User Defined (01111110)
DS1 Equipment Failure SA (00001010)
User Defined (00011010)
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...