Test Results
216
MAX-800 Series
Alarms/Errors Overview
Ethernet
Alarms
Note:
For
LOA
, and
Inv. Mapping
alarms see
Link Down
RX
: For 10/100G: There is a local or a remote fault condition. For
100/1000 Mbit/s: No bits/clock sync (PMA/PMD Link down), including
LOS. For 10 Mbit/s: No data or no Normal Link Pulse (NLP) are
received.
Local Fault Det
1
(Local Fault Detected)
RX
: At least one of the following events is detected: Loss of bit
synchronization, Loss of Block synchronization, WIS Link down, or
High BER.
Local Fault Rcd
(Local Fault Received)
RX
: The received data path contains the
Local Fault
signal.
Remote Fault
RX
: The received data path contains the
Remote Fault
status.
Hi-BER
(High-Bit Error Ratio) - (Available with 100GE interface).
RX
: The bit error ratio is > 10
-4
on a fixed time period; 500
μ
s for 100G.
1. Available with Ethernet 10/100 Gbit/s interface.