Test Setup - Test Configurator, Timer, and System
140
MAX-800 Series
RFC 2544 - Global
Coupled
is available with
Bidirectional
flow direction. When the
Coupled
check box is:
Cleared, the decision to increase or decrease the TX Rate of the
next iteration is taken independently per direction.
Selected, the decision to increase or decrease the TX Rate of the
next iteration is taken commonly for both directions.
Rate Unit
determines the unit used to display the rate values:
%
,
Mbit/s
, or
Gbit/s
.
Pass/Fail Verdict
check box when selected (default) enables the use
of the pass/fail verdict.
Subtests and Estimated Time
Subtests
allows enabling the
Throughput
,
Back-to-Back
,
Frame Loss
,
and
Latency
subtests individually.
Estimated Time (H:MM)
indicates the estimated time required to
complete each subtest at best conditions. The total estimated time to
complete all subtests is also displayed.
Frame Distribution
Frame Distribution
allows selecting either
RFC 2544
(default) or
User
Defined
distribution.
Quantity
is only available when
User Defined
is selected and allows
selecting the number of frames, from
1
to
10
(
7
by default), in the
distribution.
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...