Test Results
232
MAX-800 Series
Alarms/Errors Overview
OPUx
Note:
OPUx is displayed under ODUx alarms/errors group.
Alarms
AIS
(Alarm Indication Signal)
RX
: A PRBS11 pattern is received indicating a failure of the client
signal.
TX:
Generates a PRBS11 pattern.
CSF
(Client Signal Fail)
RX
: Bit 1 of the OPUk PSI[2] byte is set to “1” indicating a failure of the
client signal mapped into the OPUk of the OTN signal.
TX
: Sets the bit 1 of the OPUk PSI[2] byte to “1”.
PLM
(Payload Mismatch) is available when OPU-PLM check box is
selected.
RX
: The Payload Structure Identifier (PSI) field does not match the
expected PT for at least 3 consecutive frames.
MSIM Monitoring
check box when selected (default) monitors the
MSIM
alarm.