Test Functions
346
MAX-800 Series
OH - SONET/SDH
B2
: BIP-8
SONET: The BIP-8 (Bit-Interleaved Parity) byte provides line error
monitoring. This byte is only defined for the first STS-1/STM-1 frame of a
composite signal. The byte is calculated by performing a routine
even-parity check over all bits of the LOH and the STS-1 frame capacity
of the previous frame of a composite signal (STS-1 to STS-n). Note that
the SOH is not used to calculate the parity check.
SDH: The MS BIP-N*24 (Bit-Interleaved Parity) byte provides line error
monitoring. The byte is calculated by performing a routine even-parity
check over all bits of the MSOH and the STM-N frame of the previous
STM-N frame. Note that the RSOH is not used to calculate the parity
check.
K1
and
K2
: Automatic Protection Switching (APS): The K1 and K2 bytes
communicate APS between two LTE. These bytes are only defined for
the first STS-1/STM-1 frame of a composite signal.
D4
through
D12
: Data Communications Channel (DCC): The D4
through D12 bytes provide a 576 Kbit/s data communications channel
between two LTEs for administration, monitoring and other
communications. These bytes are only defined for the first STS-1/STM-1
frame of a composite signal.
S1/Z1 (SONET)
S1
: Synchronization Status: The S1 byte is used to carry the
synchronization status of the SONET device. This byte is only defined
for the first STS-1/STM-1 frame of a composite signal.
Z1
: Growth. This byte is located in the second STS-1 through STS-n
frame of a composite signal (STS-1 #2, STS-1 #3, up to STS-1 #N of a
OC-N (N>3) signal).
S1
(SDH): Synchronization Status. Bits 5 to 8 of the S1 byte are used to
carry the synchronization messages of the SDH device. This byte is only
defined for the first STS-1/STM-1 frame of a composite signal.
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...