Glossary
MaxTester
443
G.709 Optical Transport Network (OTN)
As depicted above, to create an OTU frame, a client signal rate is first
adapted at the OPU layer. The adaptation consists of adjusting the client
signal rate to the OPU rate. Its overhead contains information to support
the adaptation of the client signal. Once adapted, the OPU is mapped into
the ODU. The ODU maps the OPU and adds the overhead necessary to
ensure end-to-end supervision and tandem connection monitoring (up to
six levels). Finally, the ODU is mapped into an OTU, which provides
framing as well as section monitoring and FEC.
Following the OTN structure presented in figure
on page 442, OTUks (k = 1, 2, 3) are transported using the OCh;
each unit is assigned a specific wavelength of the ITU grid. Several
channels can be mapped into the OMS and then transported via the OTS
layer. The OCh, OMS and OTS layers each have their own overhead for
management purposes at the optical level. The overhead of these optical
layers is transported outside of the ITU grid in an out-of-band channel
called the optical supervisory channel (OSC).
When the OTU frame structure is complete (OPU, ODU and OTU), ITU
G.709 provides OAM&P functions that are supported by the overhead.
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...