Test Results
252
MAX-800 Series
Alarms/Errors Overview
ERDI-PSD
(Enhanced RDI - Path Server Defect)
RX
: Bits 5, 6 and 7 of the G1 byte contain the “101” pattern in five to ten
consecutive frames.
TX
: Generates a “101” pattern for bits 5, 6 and 7 of the G1 byte.
ERDI-PCD
(Enhanced RDI - Path Connectivity Defect)
RX
: Bits 5, 6 and 7 of the G1 byte contain the “110” pattern in five to ten
consecutive frames.
TX
: Generates a “110” pattern for bits 5, 6 and 7 of the G1 byte.
ERDI-PPD
(Enhanced RDI - Path Payload Defect)
RX
: Bits 5, 6 and 7 of the G1 byte contain the “010” pattern in five to ten
consecutive frames.
TX
: Generates a “010” pattern for bits 5, 6 and 7 of the G1 byte.
PLM-P/UNEQ-P
(Payload Label Mismatch - Path / Unequipped - Path)
check box when selected (cleared by default) enables the Signal Label
Mismatch for the expected message defined as well as
UNEQ-P
monitoring.