Test Setup - Test Configurator, Timer, and System
MaxTester
85
Cable Test
Cable Test
From the
Test
menu, tap
Setup
,
Test Configurator
, and the test block.
Global Options
Wiring Standard
is the pin-to-pair assignment corresponding to the
UTP cable used:
T568A
(default) or
T568B
.
Length Unit
is the unit used for cable length and distance to fault
results:
Meter
(default) or
Feet
.
Pass/Fail Verdict
Pass/Fail Verdict
check box when selected (default) enables the cable
test pass/fail verdict and allows setting the threshold values.
Prop. Delay Threshold (ns)
is the maximum time for a pulse to
reach the far end:
0
to
1000
ns (default is
1000
ns for 10 Mbit/s,
556
ns for 100 Mbit/s, and
570
ns for 1 Gbit/s).