Test Setup - Test Configurator, Timer, and System
MaxTester
113
Interface
For EtherBERT test application:
Remote Fault Emulation
check box when selected, generates
Remote
Fault
ordered sets when a
Link Fault
is received. Only available with
EtherBERT on 890 and 890Q models, 10GE (all framing at the exception
of
Seed A/B
and
PRBS31 Unscrambled
), and 40GE/100GE (
Framed
Layer 2
and up.
For Ethernet test application:
For optical interfaces, the
Local Fault Detected
,
Local Fault Received
,
Remote Fault
,
LOA
,
Hi-BER
, and/or
WIS Link
(10GE WAN) alarm
status are displayed. Refer to
on page 220 for more information.
Auto-Negotiation
check box is available with
10/100/1000M Electrical
and
1GE Optical
interfaces. When the
Auto-Negotiation
check box is
selected the test application indicates to the remote port which
parameters to use. The
Auto-Negotiation
check box is automatically
selected (not configurable) for 1GE Electrical interface and when using
an active copper SFP.
Note:
When the
Auto-Negotiation
check box is selected, the port
Speed
,
Duplex
,
Flow Control
, and
Local Clock
parameters can be set. Those settings are
not applied immediately to the port, they are used only when the
negotiation process is started and take effect only when the
auto-negotiation succeeds. However current settings are applied
immediately to the port when the
Auto-Negotiation
check box is cleared.
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...