Test Functions
MaxTester
341
OH - OTN
Row 3
TCM3/TCM2/TCM1
, columns 1-9, ODU OH: See
TCM6/TCM5/TCM4
on
page 340 for more information.
PM
, column 10-12, ODU OH: The Path Monitoring overhead contains
the following bytes.
The first PM byte (column 10) contains the TTI byte that is not
configurable.
The second PM byte (column 11) contains the BIP-8 byte and is
automatically generated for each frame. This byte is not configurable.
The third PM byte (column 12) contains the following sub-fields. This
byte is configurable from
00
to
FF
. The default value is
01
.
EXP
, column 13-14, ODU OH: The two Experimental overhead bytes are
configurable form
00
(default for each byte) to
FF
.
RES
, column 15, ODU OH: The Reserved (RES) bytes are configurable
from
00
(default) to
FF
.
JC
, column 16, OPU OH:
Bits 1-6, Reserved (RES), are configurable from binary
000000
(default) to
111111
.
Bits 7-8, Justification Control (JC), are configurable from binary
00
(default) to
11
. Not available with ODU mux. Changing the JC value
will corrupt the payload.
Row 4
GCC1
, column 1-2, ODU OH: The two General Communication
Channel-1 bytes are configurable from
00
(default for each byte) to
FF
.
Not configurable when GCC1 check box is selected from
Bit 1-4
Bit 5
Bit 6-8
BEI
BDI
STAT
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...