Test Setup - Test Configurator, Timer, and System
MaxTester
145
RFC 2544 - Subtests
Back-to-Back
The objective of this test is to find the maximum number of frames that can
be sent at maximum throughput without frame loss. A burst of frames
(
Burst Time
) is sent with minimum inter-frame gaps to the device under
test and the number of forwarded frames is counted. If the count of
transmitted frames is equal to the number of forwarded frames, the length
of the burst is increased and the test is rerun. If the number of forwarded
frames is less than the number of transmitted frames, the length of the
burst is reduced and the test is rerun. The Back-to-Back value is the
number of frames in the longest burst that the Device Under Test (DUT)
can handle without the loss of any frames. The test performs the number of
defined trials (
Trials
). The
Accuracy
and
Acceptable Errors
settings
specify how precise that result must be. The test is performed for each
defined frame size.
Burst Time
is expressed in seconds:
1
(default) to
5
seconds.
Trials
represents the number of times the Back-to-Back test will be
generated:
1
(default) to
100
trials.
Accuracy (Frames)
is the accuracy measurement value in frames:
1
(default) to
50
frames.
Acceptable Errors
represents the number of acceptable errors for the
test:
0
(default) to
10
.
Bursts
represents the number of burst that will be generated:
1
(default) to
10
.
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...