Test Setup - Test Configurator, Timer, and System
98
MAX-800 Series
EtherSAM - Burst
Parameters
Number of Burst Sequence
is the number of times,
1
to
100
(default
is
2
), the burst sequence will be repeated for the CBS and EBS tests.
Refill Delay Ratio (%)
is the percentage of time required to refill the
CBS/EBS
token buckets. The refill delay ratio is used for post-burst
delay and the remaining percentage is applied to the pre-burst delay.
The
Refill Delay Ratio
is configurable from
0
to
100
percent
(
50
percent is the default as well as the standard’s minimum
recommended value).
Burst/IR Frame Ratio (%)
is the percentage of frames transmitted at
CIR
rate for the
CBS
test and the percentage of frames transmitted at
CIR+EIR
rate for the
EBS
test. The
Burst/IR Frame Ratio
is
configurable from
10
to
90
percent (
90
percent is the default as well as
the standard’s recommended percentage value).
Table
Note:
Test time values are only displayed for enabled services.
Service No
indicates the service number.
Service Name
indicates the name of the service.
Direction
, available with
Dual Test Set
or
Dual Port
topology,
indicates respectively results for local (
L
) and remote (
R
) directions, or
port to port directions.
CBS Test Time (s)
indicates the total time required to perform all burst
sequence iterations of the CBS test for this service.
EBS Test Time (s)
indicates the total time required to perform all burst
sequence iterations of the EBS test for this service.
Total Burst Test Time (s)
indicates the total time required to perform
all burst sequence iterations of both
CBS
and
EBS
tests for this service.
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...