Test Setup - Test Configurator, Timer, and System
MaxTester
175
Signal - Signal Configuration (OTN)
Signal - Signal Configuration (OTN)
Note:
The following signal configuration parameters are available from the
interface block.
From the
Test
menu, tap
Setup
,
Test Configurator
, the interface block,
and on the
Signal
tab.
OTU4
,
OTU2
, or
OTU1
Note:
At least one of the two check boxes,
FEC
or
Scrambler
, must be selected in
order to prevent potential alarms caused by a lack of bit transition on the
optical signal. For example to disable
FEC
, first select the
Scrambler
check
box then clear the
FEC
check box.
FEC
check box when selected (default) enables the FEC in TX/RX
and allows detecting, reporting, and correcting up to 8 symbol
errors (Correctable) per codeword. If there are over 8 symbol
errors detected, they are reported as uncorrectable errors.
FEC-CORR Alarming
check box when cleared (selected by
default) does not report the
FEC-CORR
error status
(current/history), seconds, and does not affect the global test
verdict. Only available when
FEC
is enabled.
Scrambler
check box when selected (default) provides enough
“0” and “1” transitions on the optical signal for clock recovery.
Note:
When the
Scrambler
check box is cleared, the receiver circuitry is forced to
operate in a condition which is outside of the specified OTN operating
conditions, potentially causing alarms/errors. This configuration can be
used for special analysis in a lab environment.
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...