Test Results
MaxTester
235
Alarms/Errors Overview
LOF
(Loss of Frame)
RX
: OOF is present for at least 3 ms.
TX
: Generates error in all FAS bits continuously.
LOM
(Loss Of Multiframe)
RX
: OOM is present for at least 3 ms
TX
: Generates error in MFAS bits continuously.
OOF
(Out-Of-Frame)
RX
: FAS (bytes 3, 4, and 5) are in error for at least 5 consecutive OTU
frames.
TX
: Generates error in all FAS bits for 5 consecutive OTU frames.
OOM
(Out-Of-Multiframe)
RX
: MFAS are in error for at least 5 consecutive OTU frames.
TX
: Generates error in multiframe number for 5 consecutive OTU
frames.
TIM
(Trace Identifier Mismatch)
RX
: Expected SM SAPI and/or SM DAPI do not match the received SM
SAPI and/or DAPI for at least 3 consecutive TTI. This alarm is only
available when the Enable TIM SAPI OTU-TIM and/or DAPI OTU-TIM
check boxes are selected from page 199.