Traffic Analyzer Tabs
Ethernet and Fibre Channel Application
193
FC TX
PHY Error Injection
Type
: The following errors are available with both manual and
automated injection modes:
Symbol Error
for FC 1x/2x/4x, and
Block
Error
for FC 10x.
Amount
: Allows the selection of the amount of manual error to be
generated. Choices are
1
through
50
. The default setting is
1
.
Send
button: Press
Send
to manually generate error(s) according to
the error type and the amount of error.
Rate
: Press the
Rate
field to select the rate for the automated error.
Choices are:
1.0E-02
,
1.0E-03
,
1.0E-04
,
1.0E-05
,
1.0E-06
,
1.0E-07
,
1.0E-08
,
1.0E-09
or user definable from
1.0E-09
to
1.0E-02
. The default
setting is
1.0E-04
.
Continuous
: Generates the selected error for each generated frame
when the
Continuous
check box is selected while the
On/Off
button is
enabled (On). The
Continuous
check box is cleared by default.
On/Off
button: The
On/Off
button is used to activate/deactivate the
selected automated error at the rate specified or continuously. This
setting is disabled (Off) by default.