RFC 2544 Tabs
310
IQS-8500 Series and IQS-8120NGE/8130NGE
Back-to-Back
Configuration
Max. time worth of frame (MM:SS)
: Choices are
1
to
5
seconds. The
default setting is
1
second (00:01).
Accuracy (Frames)
: Enter the Accuracy measurement value in frames.
Choices are
1
to
50
frames. The default setting is
1
.
Nb of Acceptable Errors
: Select the number of acceptable errors for
the test. Choices are
0
to
10
errors. The default setting is
0
error.
Nb of Trials to Average
: Select the number of times the throughput
test will be generated. Choices are
1
to
100
trials. The default setting is
1
trial.
Nb of Burst
: Select the number of burst that will be generated. Choices
are
1
to
10
Bursts. The default setting is
1
Burst.
Minimum Test Time (Seconds)
: Indicates the minimum time the test
requires to run at best condition. The minimum test time is calculated
and updated once the test is started.