Creating and Starting a Test Case
110
IQS-8500 Series and IQS-8120NGE/8130NGE
Ethernet Smart Loopback Test Case
1f.
For IQS-8510B, select the
port number by pressing
on
Port 1
or
Port 2
.
For IQS-8510B in
Dual
Ports
, select the first port
and proceed with the rest
of the configuration for the
first port. However, before
pressing
Finish
, press
Back
several times to
return to the port setup
window, select the second
port and proceed with the
rest of the configuration for the second port.
1g.
For Electrical RJ-45, if required, select
the
Ethernet port crossover
check box
to inverse the pin-to-pair assignment of
the UTP cable used.
Note:
At this point you should have a link up indicated in the
Tree
view tab. A
green LED indicates a link up while a red LED indicates a link down. For
electrical port, if the link is down, make sure that the
Ethernet port
crossover
setting is correct.
1h.
Press
Next
.