Expert Mode Tabs
428
IQS-8500 Series and IQS-8120NGE/8130NGE
Throughput (RFC 2544)
Throughput (RFC 2544)
Press
TEST
,
Expert Mode
, and
Throughput
.
Enable Criteria
: Allows to enable
Throughput
Pass/Fail
criteria. This
setting is disabled by default.
Note:
Both
Enable Criteria
and the test itself (see Global Configuration
) have to be enabled for a specific test to be able to change its
criteria values.
Frame Size
: Indicates the frame sizes selected for the test.
TX-to-RX/P1-to-P2/P2-to-P1
/
Local to Remote
/
Remote to Local
: For
each frame size, enter the minimum throughput values allowed before
declaring a
Fail
condition. The default values are the maximum
throughput.
P1-to-P2/P2-to-P1
is only available with IQS-8510B.
Status
: Indicates the real-time pass/fail condition.
Grey LED
: Indicates that
Expert Mode
is disabled or the test did not
run yet.
Green LED
: Indicates that the threshold is respected (
Pass
).
Red LED
: Indicates that the threshold is not respected (
Fail
).
Copy From Measurement
button: Copy the performance results from
the test that ran previously and use it as the
Pass
/
Fail
criteria. If no test
ran before, default values used will be
0 bps
.