WIS Tabs
Ethernet and Fibre Channel Application
245
WIS TX
ERDI-PCD
(Enhanced RDI - Path Connectivity Defect): Generates a
“110” pattern for bits 5, 6 and 7 of the G1 byte.
ERDI-PPD
(Enhanced RDI - Path Payload Defect): Generates a
“010” pattern for bits 5, 6 and 7 of the G1 byte.
On/Off
button: The On/Off button is used to activate/deactivate the
selected alarm. This setting is disabled (Off) by default.
Note:
For the
SEF
alarm, the On/Off button turns Off automatically once the
SEF
alarm has been sent.
Error Injection
Note:
Error injection is available with BERT test only.
Type
: The following errors are available with both
Manual
and
Automated
injection modes:
B1
,
B2
,
B3
,
REI-L
, and
REI-P
.
Amount
: Select the amount of manual error to be generated.
Choices are
1
to
50
. The default setting is
1
.
Send
button: Press
Send
to manually generate error(s) according to
the error type and the selected amount of errors.
Rate
: Press the Rate field to select the rate for the automated error.
Choices are:
1.0E-2
,
1.0E-3
,
1.0E-4
,
1.0E-5
,
1.0E-6
,
1.0E-7
,
1.0E-8
,
1.0E-9
, or user definable from
1.0E-09
to
6.4E-06
. The default setting is
1.0E-06
.
Continuous
: Generates the selected error for each generated frame
when the
Continuous
check box is selected while the
On/Off
button is
enabled (On). The
Continuous
check box is cleared by default.
On/Off
button: The On/Off button is used to activate/deactivate the
selected automated error at the rate specified or continuously. This
setting is disabled (Off) by default.