EtherSAM Tabs
348
IQS-8500 Series and IQS-8120NGE/8130NGE
Service Configuration Test (Results)
Ramp and Burst Tests Table
Step
, for ramp test, indicates the ramp step number or name.
CIR %
, for ramp test, indicates the percentage of CIR used for each
Burst Test
: indicates the two burst tests: CBS and EBS.
Burst Size
indicates the size of the burst used for the test (see
Direction
: Direction is displayed for dual test set test case providing
bidirectional data.
L -> R
indicates results from local to remote direction.
R -> L
indicates results from remote to local direction.
Frame Loss (%)
indicates the percentage of frames that are lost. Note
that the reported value is the maximum percentage of Frame Loss
from all the burst sequences and ramp steps excluding the
CIR+EIR
,
EBS
, and
Traffic Policing
steps.
Max Jitter (ms)
indicates the maximum measured delay variation.
Max Round-Trip Latency (ms)
indicates the maximum measured
round trip latency (delay). For IQS-8120NGE and IQS-8130NGE in Dual
Test Set, only available with round-trip latency measurement mode.
Max Latency (ms)
indicates the maximum measured one way latency
(delay). Only available with IQS-8120NGE and IQS-8130NGE in Dual
Test Set one-way latency measurement mode.
Not Measurable
is
displayed when the maximum latency is higher than 500 ms.