EtherSAM Tabs
Ethernet and Fibre Channel Application
333
Services (Configuration)
PBB-TE
indicates and allows to change the selected frame PBB-TE
destination address. PBB-TE is only displayed when PBB-TE has been
enabled. Refer to
PBB-TE Interface configuration
information.
MPLS
indicates and allows to change the selected frame label. MPLS is
only displayed when MPLS has been enabled. Refer to
on page 499 for more information.
UDP
indicates and allows to change the selected source and
destination UDP ports. UDP is only available when the Framing’s
Transport is set to UDP. Refer to
more information.
TCP
indicates and allows to change the selected source and
destination TCP ports. TCP is only available when the Framing’s
Transport is set to TCP. Refer to
more information.
IP TOS
indicates and allows to change the selected frame IP TOS
on page 502 for more information.
SLA Parameters
The SLA (Service-Level Agreement) parameters allows defining the
pass/fail verdict thresholds for the service. Use the check boxes to enable
the pass/fail verdict for these parameters and enter the threshold values.
Information Rate
Note:
At least one check box (
CIR
or
CIR+EIR
) has to be selected. Thus, clearing
the CIR check box while CIR+EIR check box is cleared, will automatically
select the CIR+EIR check box and vice versa.
CIR
(Committed Information Rate) sets the service rate guaranteed by
the SLA. The CIR check box is selected by default and its value sets to
50% of the line rate. CIR and preceding steps are not performed for
services that have the CIR check box cleared.