EtherSAM Tabs
338
IQS-8500 Series and IQS-8120NGE/8130NGE
Ramp (Configuration)
Step List
Step
indicates the step number. Up to 10 steps may be configured; up
to 7 pre-CIR,
CIR
,
CIR+EIR
, and
Traffic Policing
. Steps are
automatically sorted by the % of CIR value.
Value (% of CIR)
indicates a percentage of
CIR
,
CIR+EIR
, and/or
Traffic Policing
RX rate (throughput) level.
CIR+EIR
is part of the step
list as soon as it is enabled for at least one service. However, the
CIR+EIR step will only be part of the test for services that have the
CIR+EIR check box selected.
Edit
button allows to edit a ramp step. To modify a ramp step, press
the
Edit
button and enter the new CIR percentage.
Add
button allows to add a new ramp step. To add a new ramp step,
press he
Add
button and enter the CIR percentage.
Delete
button allows to delete the selected ramp step. To delete a
ramp step, select the ramp step from the list and press on the
Delete
button.
CIR
,
CIR+EIR
and
Traffic Policing
steps cannot be deleted. To
remove
CIR+EIR
,
CIR
, and/or
Traffic Policing
from the list, clear the
corresponding check box from the
Services
tab for all services.
Default
button allows to return to the default ramp steps.
Step Time
The step time represents the test duration for each ramp step (from 5 to 60
seconds).
Ramp Duration
The ramp duration indicates the total time required to perform all the ramp
steps for each service.