3.3.3
Array antenna - fix version
Prerequisites
Still Pipe antenna requirements
for information on mounting considerations before
installing the gauge on the tank.
Measure the pipe inner diameter before closing the still-pipe. Enter this value during the
configuration.
Follow this instruction when installing the Rosemount 5900S with Array Antenna Fixed
version.
Procedure
1. Insert the Antenna Waveguide into the flange hole, and place the antenna label into
position, with text down.
$
%
&
A. Nut
B. Antenna label plate
C. Antenna Waveguide
2. Tighten the nut.
$
A. Nut
3. Secure the nut by folding the tab on the label plate over the nut.
4. Bend the antenna label plate at the slot mark to a position with the text clearly
visible.
Reference Manual
Installation
00809-0100-5900
September 2019
Rosemount 5900S Radar Level Gauge
63